Hillrom and Welch Allyn are a part of Baxter.
Item #: 1C8454
Extension Set Minivolume with INTERLINK Injection Site and Male Luer Lock Adapter. Approximately Volume 0.58 mL. Approximately length 14” (35 cm). Contains DEHP. Sterile Package, Nonpyrogenic.
Item #: 2B2454
40 mmol/L Potassium Chloride in 5% Dextrose and 0.9% Sodium Chloride Injection, USP, 1000 mL VIAFLEX PVC Container.
Item #: 2C1154KP
Infusor SV 1,2,3:
Nominal Flow Rate- 1,2,3 mL/h:
Accuracy- +/- 10%:
Calibrating Diluent- D5W:
Calibrating Temperature- 33.3 Celsius:
Nominal + Residual Volume- 96 mL + 1 mL:
Maximum Volume- 130 mL:
Nominal Delivery Time- 96-48-32 hours
Item #: 2C1155KP
Infusor LV 2,3,5:
Nominal Flow Rate- 2,3,5 mL/h:
Accuracy- +/- 10%:
Calibrating Diluent- D5W:
Calibrating Temperature- 33.3 Celsius:
Nominal + Residual Volume- 240 mL + 3 mL:
Maximum Volume- 300 mL:
Nominal Delivery Time- 120-80-48 hours
Item #: 2C1168K
Infusor XLV 8:
Nominal Flow Rate- 8mL/h:
Accuracy- +/- 15%:
Calibrating Diluent- NS:
Calibrating Temperature- 31.1 Celsius:
Nominal + Residual Volume- 576 mL +5mL:
Maximum Volume- 600 mL
Nominal Delivery Time- 3 days
Item #: 2C2118K
NDEHP Intermate SV 200
Nominal Flow Rate: 200 mL/h
Accuracy: +/- 15%
Calibrating Diluent: NS
Calibrating Temperature: 21.1 Celsius
Nominal + Residual Volume: 100 mL + 1 mL
Maximum Volume: 105 mL
Nominal Delivery Time: 30 minutes
Item #: 2C2120K
NDEHP Intermate LV 100
Nominal Flow Rate: 100 mL/h
Accuracy: +/- 15%
Calibrating Diluent: NS
Calibrating Temperature: 21.1 Celsius
Nominal + Residual Volume: 250 mL + 3 mL
Maximum Volume: 275 mL
Nominal Delivery Time: 2.5 hours
Item #: 2C2122K
NDEHP Intermate LV 250
Nominal Flow Rate: 250mL/hr
Accuracy: +/- 15%
Calibrating Diluent: NS
Calibrating Temperature: 21.1 Celsius
Nominal + Residual Volume: 250 mL + 3 mL
Maximum Volume: 275 mL
Nominal Delivery Time: 1 hour
Item #: 2C2123K
NDEHP Intermate XLV 250
Nominal Flow Rate- 250 mL/h
Accuracy- +/- 15%
Calibrating Diluent- NS
Calibrating Temperature- 21.1 Celsius
Nominal + Residual Volume- 500mL + 5 mL
Maximum Volume- 550 mL
Nominal Delivery Time- 2 hours
Solution Set with Non-Vented Spike and Male Luer Lock Adapter with Retractable Collar. Approximately 60 drops/mL. Approximate Length 109 (2.8 m). Contains DEHP. Sterile package, nonpyrogenic.
Item #: 2E7554
Solution Set Non-Vented Spike, Male Epidural Non-Luer Lock Adapter (NRFit). For Epidural Use. Approximately 60 drops/mL. Approximate length 108 (2.8 m). Contains DEHP. Sterile Package. Nonpyrogenic.
CONTINU-FLO Solution Set with Non-Vented, 3 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 109" (2.8 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
Item #: 2N3354
Extension Set, Micro-volume, with Male Luer Lock Adapter and pinch clamp. Approximate Priming Volume 0.47 mL. Approximate Length 79 (200 cm). Non-DEHP. Sterile package, Nonpyrogenic.
Item #: 2N3356
Extension Set, Mini-volume, with Male Luer Lock Adapter and pinch clamp. Approximate Priming Volume 1.1 mL. Approximate Length 79" (200 cm). Non-DEHP. Sterile package, Nonpyrogenic.
Extension Set with 0.2 Micron Filter, Micro-volume, Male Luer Lock Adapter and pinch clamp. Approximate Priming Volume 0.88 mL. Approximate Length 79 (200 cm). Non-DEHP. Sterile package, Nonpyrogenic.
Item #: 2N3358
Extension Set, Micro-volume, with Male Luer Lock Adapter. Approximate Priming Volume 0.4 mL. Approximate Length 59 (150 cm). Non-DEHP. Sterile package, Nonpyrogenic.
Added to Your Cart
Product Availability by Store Location
Hours