Hillrom and Welch Allyn are a part of Baxter.
text.skipToContent text.skipToNavigation
481 Results found
Solution Set, Non-Vented, 0.2 Micron Filter, 10 drops/mL, 99 (2.5 m)
Solution Set with Non-Vented Spike, 0.2 Micron Downstream Filter, and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 99 (2.5 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
Y-Type Blood/Solution Set with Standard Blood Filter 170 to 260 Micron and Pressure Pump, 100 (2.5  m)
Y-Type Blood/Solution Set with Large Standard Blood Filter (170 to 260 Micron Filter) and Pressure Pump and Male Luer Lock Adapter. Approximate length 100 (2.5 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Y-Type Blood/Solution Set with Standard Blood Filter 170 to 260 Micron, 98 (2.5 m)
Y-Type Blood/Solution Set with Large Standard Blood Filter (170 to 260 Micron Filter) and Male Luer Lock Adapter. Approximate length 98 (2.5 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Straight-Type Blood Set with Standard Blood Filter 170 to 260 Micron, 10 drops/mL,  88 (2.2 m)
Straight-Type Blood Set with Standard Blood Filter (170 to 260 Micron Filter )and Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate length 88 (2.2 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Solution Set, Non-Vented, 10 drops/mL,  101 (2.6 m)
Solution Set with Non-Vented Spike and Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 101 (2.6 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, 3 CLEARLINK Luer Activated Valves, Backcheck Valve, Retractable Collar, 10 drops/mL, 107 (2.7 m)
CONTINU-FLO Solution Set with Non-Vented Spike, 3 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 107 (2.7 m). Contains DEHP. Fluid path is sterile, non
Solution Set, Non-Vented, CLEARLINK Luer Activated Valve, 10 drops/mL, 92 (2.3 m)
Solution set with Non-Vented Spike, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 92 (2.3 m). Fluid path is sterile, nonpyrogenic.
Solution Set, DUO-VENT, CLEARLINK Luer Activated Valve, 10 drops/mL, 91.5 (2.3 m)
Solution Set with DUO-VENT Spike, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 91.5 (2/3 m). Fluid path is sterile, nonpyrogenic.
Solution Set, DUO-VENT, 2 CLEARLINK Luer Activated Valves, 60 drops/mL, 100 (2.5 m)
Solution Set with DUO-VENT Spike, 2 CLEARLINK Luer Activated Valves, and Male Luer Lock Adapter. Approximately 60 drops/mL. Approximate Length 100 (2.5 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, 2 CLEARLINK Luer Activated Valves, Backcheck Valve, 10 drops/mL, 104 (2.6 m)
CONTINU-FLO Solution Set with Non-Vented Spike, 2 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 104 (2.6 m). Contains DEHP. Fluid path is sterile, nonpyr
CONTINU-FLO Solution Set, Non-Vented, 3 CLEARLINK Luer Activated Valves, Backcheck Valve, 10 drops/mL, 105 (2.7 m)
CONTINU-FLO Solution Set with Non-Vented Spike, 3 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 105 (2.7 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Y-Type Blood/Solution Set with Standard Blood Filter 170 to 260 Micron and Pressure Pump, 2 CLEARLINK Luer Activated Valves, 103 (2.6 m)
Y-Type Blood/Solution Set with Large Standard Blood Filter (170 to 260 Micron Filter) and Pressure Pump, 2 CLEARLINK Luer Activated Valves, and Male Luer Lock Adapter. Approximate length 103 (2.6 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Universal Vial Adapter, CLEARLINK Luer Activated
Universal Vial Adapter, CLEARLINK Luer Activated , Non-DEHP, Non-PVC. Sterile package, Nonpyrogenic.
Universal Vial Adapter, INTERLINK System
Universal Vial Adapter, INTERLINK System. Intended for use in the reconstitution and withdrawal of solutions from drug vials. Non-DEHP. Non-PVC. Sterile package, Nonpyrogenic.
Tamper-Resistent Add-Port Cap. Red plastic hinged cap, sealed on one end.
Tamper-Resistent Add-Port Cap, Red plastic hinged cap, sealed on one end. After additives are made, place Add-Port Cap over additive port and snap closed. Once attached, the Add-Port Cap is designed not to be removed. Non-Sterile.
Tamper Evident Oral Dispenser Cap, Three-Part Plastic Cap for ExactaMed Oral Dispenser. Red
Tamper Evident Oral Dispenser Cap. Three-part plastic cap used to indicate tampering on an EXACTAMED Oral Dispenser. Secure, non-sterile cap requires user to break off outer sleeve to dispense medication. A red ring remains in place, indicating the outer sleeve has been removed. Red
Straight-Type Extension Set, INTERLINK Injection Site, 1.2 Micron Filter, Standard Bore, Fixed Collar, 21" (53 cm)
Extension Set with 1.2 Micron Downstream Air Eliminating Filter and INTERLINK Injection Site with Fixed Collar. Approximately Volume 5.1 mL. Approximate Length 21" (53 cm). Non-DEHP. Fluid path is sterile, Nonpyrogenic.
Straight-Type Extension Set, Standard Bore, 2 CLEARLINK Luer Activated Valves, Retractable Collar, 42" (107 cm)
Extension Set with 2 CLEARLINK Luer Activated Valves and Male Luer Lock Adapter with Retractable Collar. Approximate Volume 6.2 mL. Approximate Length 42" (107 cm). Contains DEHP. Fluid path is Sterile, Nonpyrogenic.