Hillrom and Welch Allyn are a part of Baxter.
text.skipToContent text.skipToNavigation
  • 1(current)
  • 2
  • 3
71 Results found
CONTINU-FLO Solution Set, Non-Vented, 3 CLEARLINK Luer Activated Valves, Backcheck Valve, Retractable Collar, 10 drops/mL, 109" (2.8 m), Non-DEHP
CONTINU-FLO Solution Set with Non-Vented, 3 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 109" (2.8 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, 3 CLEARLINK Luer Activated Valves, Backcheck Valve, Retractable Collar., 10 drops/mL, 120" (3.0 m)), Non-DEHP
CONTINU-FLO Solution Set with Non-Vented Spike, 3 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 120" (3 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, 3 CLEARLINK Luer Activated Valves, Backcheck Valve,  Retractable Collar, 60 drops/mL, 105" (2.7 m), Non-DEHP
CONTINU-FLO Solution Set with Non-Vented Spike, 3 CLEARLINK Injection Sites, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 60 drops/mL. Approximate Length 117" (2.9 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
BURETROL Solution Set, 150 mL Burette Drip Chamber Filter Valve, 3 CLEARLINK Luer Activated Valves, 60 drops/mL, 105" (2.7 m), Non-DEHP
Non-DEHP BURETROL Solution Set with 150 mL Burette Drip Chamber Filter Valve, 3 CLEARLINK Luer Activated Valves (1 in burette), Male Luer Lock Adapter with Retractable Collar. Approximately 60 drops/mL. Approximate length 105" (2.7 m). Non- DEHP. Fluid path is sterile, nonpyrogenic.
Solution Set, Non-Vented, 10 drops/mL,  101" (2.6 m)
Solution Set with Non-Vent Spike and Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 101" (2.6 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
Solution Set, Non-Vented, 10 drops/mL,  69" (1.7 m), Sterile package
Solution Set with Non-Vent Spike and Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 69" (1.7 m). Contains DEHP. Sterile package, nonpyrogenic.
IV Fat Emulsion Administration Set, Non-Vented, 10 drops/mL, 86" (2.2 m), Non-DEHP
IV Fat Emulsion Administration Set with Non-Vented Spike and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 86" (2.2 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, 2 CLEARLINK Luer Activated Valves, Backcheck Valve plus Stopcock Manifold and 1 CLEARLINK Luer Activated Valves Extension Set. Approx. 10 drops/mL
CONTINU-FLO Solution Set with Non-Vented Spike, 2 CLEARLINK Luer Activated Valves, Backcheck Valves, Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate length 88" (2.2 m). Plus Large Bore 4-Way Stopcocks Manifold Extension Set with CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar, Approximate Volume 5.6 mL. Approximate Length 35" (88 cm). Contains DEHP. Sterile package, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, 2 CLEARLINK Luer Activated Valves, Backcheck Valve. Plus 4-Way Stopcock Extension Set with 2 CLEARLINK Luer Activated Valve
CONTINU-FLO Solution Set with Non-Vented Spike, 2 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 88" (2.2 m). Plus Large Bore 4-Way Stopcock with Rotating Male Luer Lock Extension Set with 2 CLEARLINK Luer Activated Valves and Male Luer Lock Adapter with Retractable Collar. Approximate Volume 5.4mL. Approximate length 34" (86 cm). Contains DEHP. Sterile package, nonpyrogenic.
CONTINU-FLO Solution Set , Non-Vented, 2 CLEARLINK Luer Activated Valves. Plus 4-Way Stopcock Manifold Extension Set with CLEARLINK Luer Activated Valve
CONTINU-FLO Solution Set with Non-Vented Spike, 2 CLEARLINK Luer Activated Valves, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate length 88" (2.2 m). Plus Large Bore 4-Way Stopcock Manifold Extension Set with CLEARLINK Luer Activated Valve and Male Luer Lock Adaptor with Retractable Collar. Approximate Volume 6.1 mL. Approximate Length 36" (92 cm). Contains DEHP. Sterile package, nonpyrogenic.
INTERLINK SYSTEM BASIC SOLNSET INJ SITE
INTERLINK SYSTEM BASIC SOLNSET INJ SITE
INTERLINK SOLN SET INJ. SITE L/L 60 DPM
INTERLINK SOLN SET INJ. SITE L/L 60 DPM
INTERLINK BASIC SET 92 IN.
INTERLINK BASIC SET 92 IN.
INTERLINK BASIC SOLN SET 2 INJSITES 10 DPM
INTERLINK BASIC SOLN SET 2 INJSITES 10 DPM
CONTINU-FLO Solution Set, Non-Vented, 2 INTERLINK Injection Sites. Plus 4-Way Stopcock Manifold Extension Set with INTERLINK Injection Site
CONTINU-FLO Solution Set with Non-Vented Spike, 2 INTERLINK Injection Sites, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 89" (2.3 m). Plus Large Bore 4-Way Stopcocks Manifold Extension Set with INTERLINK Injection Site and Male Luer Lock Adapter with Retractable Collar. Approximate Volume 5.5 mL. Approximate Length 35" (90 cm). Contains DEHP. Sterile package, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, 3 INTERLINK Injection Sites, Backcheck Valve. 10 drops/mL. 110" (2.8 m)
CONTINU-FLO Solution Set with Non-Vented Spike, 3 INTERLINK Injection Sites, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 110" (2.8 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, 3 INTERLINK Injection Sites, Backcheck Valve. 60 drops/mL. 106" (2.7 m)
CONTINU-FLO Solution Set with Non-Vented Spike, 3 INTERLINK Injection Site, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 60 drops/mL. Approximate Length 106" (2.7 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, 0.2 Micron Filter, 2 INTERLINK Injection Sites, Backcheck Valve. 10 drops/mL. 105" (2.7 m)
CONTINU-FLO Solution Set with Non-Vented Spike, 0.2 Micron Filter, 2 INTERLINK Injection Sites, Backcheck Valve and Male Luer Lock Adapter Retractable Collar. Approximately 10 drops/mL. Approximate Length 105" (2.7 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
  • 1(current)
  • 2
  • 3