Hillrom and Welch Allyn are a part of Baxter.
Item #: 40700BAX
Novum IQ LVP Infusion System delivers one of the safest and most technologically integrated administration experiences today.Advanced interoperability through IQ Enterprise, web-based dose error reduction system (DERS), 95% field serviceable,ove
Item #: JC4041P
Drip chamber, roller clamp, catheter adapter, 0.195” ID tubing Priming volume = 45 mL, Sterile peel pouch. Length: 82” (2.1 m)
Item #: 1C8363
Extension Set with 0.2 Micron Downstream Filter, Polyethylene Lined Tubing, Male Luer Lock Adapter. Approximately Volume 3.3 mL. Approximately Length 6.2 (15.8 cm). Fluid path does not contain DEHP, outer layer of polyethylene lined tubing contains DEHP.
Item #: 1C8454
Extension Set Minivolume with INTERLINK Injection Site and Male Luer Lock Adapter. Approximately Volume 0.58 mL. Approximately length 14” (35 cm). Contains DEHP. Sterile Package, Nonpyrogenic.
IV Fat Emulsion Administration Set with Non-Vented Spike and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 86 (2.2 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
Item #: 2C1154KP
Infusor SV 1,2,3:
Nominal Flow Rate- 1,2,3 mL/h:
Accuracy- +/- 10%:
Calibrating Diluent- D5W:
Calibrating Temperature- 33.3 Celsius:
Nominal + Residual Volume- 96 mL + 1 mL:
Maximum Volume- 130 mL:
Nominal Delivery Time- 96-48-32 hours
Item #: 2C1155KP
Infusor LV 2,3,5:
Nominal Flow Rate- 2,3,5 mL/h:
Accuracy- +/- 10%:
Calibrating Diluent- D5W:
Calibrating Temperature- 33.3 Celsius:
Nominal + Residual Volume- 240 mL + 3 mL:
Maximum Volume- 300 mL:
Nominal Delivery Time- 120-80-48 hours
Item #: 2C1168K
Infusor XLV 8:
Nominal Flow Rate- 8mL/h:
Accuracy- +/- 15%:
Calibrating Diluent- NS:
Calibrating Temperature- 31.1 Celsius:
Nominal + Residual Volume- 576 mL +5mL:
Maximum Volume- 600 mL
Nominal Delivery Time- 3 days
Item #: 2C2118K
NDEHP Intermate SV 200
Nominal Flow Rate: 200 mL/h
Accuracy: +/- 15%
Calibrating Diluent: NS
Calibrating Temperature: 21.1 Celsius
Nominal + Residual Volume: 100 mL + 1 mL
Maximum Volume: 105 mL
Nominal Delivery Time: 30 minutes
Item #: 2C2120K
NDEHP Intermate LV 100
Nominal Flow Rate: 100 mL/h
Accuracy: +/- 15%
Calibrating Diluent: NS
Calibrating Temperature: 21.1 Celsius
Nominal + Residual Volume: 250 mL + 3 mL
Maximum Volume: 275 mL
Nominal Delivery Time: 2.5 hours
Item #: 2C2122K
NDEHP Intermate LV 250
Nominal Flow Rate: 250mL/hr
Accuracy: +/- 15%
Calibrating Diluent: NS
Calibrating Temperature: 21.1 Celsius
Nominal + Residual Volume: 250 mL + 3 mL
Maximum Volume: 275 mL
Nominal Delivery Time: 1 hour
Item #: 2C2123K
NDEHP Intermate XLV 250
Nominal Flow Rate- 250 mL/h
Accuracy- +/- 15%
Calibrating Diluent- NS
Calibrating Temperature- 21.1 Celsius
Nominal + Residual Volume- 500mL + 5 mL
Maximum Volume- 550 mL
Nominal Delivery Time- 2 hours
Added to Your Cart
Product Availability by Store Location
Hours


