text.skipToContent text.skipToNavigation
13 résultats trouvés
INTERLINK SYSTEM BASIC SOLNSET INJ SITE
Numéro de pièce : 2C6401
INTERLINK SYSTEM BASIC SOLNSET INJ SITE
IL STRAIGHT BLOOD SET/STANDARDBLD FLT DRIP CHAMB. PUMP
IL STRAIGHT BLOOD SET/STANDARDBLD FLT DRIP CHAMB. PUMP
Paclitaxel Set, Non-Vented, INTERLINK Injection Site, 0.2 Micron Filter, 10 drops/mL, 108" (2.7 m)
Paclitaxel Set Non-Vented Spike with Polyethylene Lined Tubing and INTERLINK Injection Site, 0.2 Micron Filter, Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate length 108" (2.7 m). Non-DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP; outer layer of polyethylene lined tubing contains DEHP.
Solution Set, Non-Vented, CLEARLINK Luer Activated Valve, 10 drops/mL, 76" (1.9 m)
Solution Set with Non-Vented Spike, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 76" (1.9 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
CONTINU-FLO Solution Set, Non-Vented, CLEARLINK Luer Activated Valve, Backcheck Valve, 10 drops/mL, 106" (2.7 m)
CONTINU-FLO Solution Set with Non-Vented Spike, CLEARLINK Luer Activated Valve, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 106" (2.7 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.
CL PUMP COMPATIBLE STRAIGHTBLD SET W/170/260 FLTR & 1 Y
CL PUMP COMPATIBLE STRAIGHTBLD SET W/170/260 FLTR & 1 Y
Paclitaxel Set, Non-Vented, 0.2 Micron Filter, CLEARLINK Luer Activated Valve, 10 drops/mL, 107" (2.7 m)
Paclitaxel Set Non-Vented Spike with Polyethylene Lined Tubing and CLEARLINK Luer Activated Valve, 0.2 Micron Filter, Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 107" (2.7 m). Non-DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP: Outer layer of polyethylene lined tubing contains DEHP.
IL NON-DEHP SOLN SET W/1 YAND LEVER LOCK
Numéro de pièce : 2H6401
IL NON-DEHP SOLN SET W/1 YAND LEVER LOCK
Solution Set, Non-Vented, CLEARLINK Luer Activated Valve, 10 drops/mL, 76" (1.9 m), Non-DEHP
Solution set with Non-Vented Spike, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 76" (1.9 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
Solution Set, Non-Vented, 1.2 Micron Filter, CLEARLINK Luer Activated Valve, 10 drops/mL, 107" (2.7 m), Non-DEHP
Solution Set with Non-Vented Spike, 1.2 Micron Downstream Filter, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 107" (2.7 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
Solution Set, Non-Vented, CLEARLINK Luer Activated Valve, 10 drops/mL, 76" (1.9 m), Non-DEHP
Solution Set with Non-Vented Spike, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 76" (1.9 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
Solution Set, Non-Vented, 1.2 Micron Filter, CLEARLINK Luer Activated Valve, 10 drops/mL, 107" (2.7 m), Non-DEHP
Solution Set with Non-Vented Spike, 1.2 Micron Downstream Filter, CLEARLINK Luer Activated Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 107" (2.7 m). Non-DEHP. Fluid path is sterile, nonpyrogenic.
Paclitaxel Set, Non-Vented, 0.2 Micron Filter, CLEARLINK Luer Activated Valve, 10 drops/mL, 107" (2.7 m), Non-DEHP
Paclitaxel Set Non-Vented Spike with Polyethlyene Lined Tubing and CLEARLINK Luer Activated Valve, 0.2 Micron Filter, Male Luer Lock Adapter. Approximately 10 drops/mL. Approximate Length 107" (2.7 m). Non-DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP: Outer layer of polyethylene lined tubing contains DEHP.