146 Results found
Infusor SV 1, 2, 3
Item #: 2C1154KP
Infusor SV 1, 2, 3 Débit nominal: 1, 2, 3 mL/h Précision: +/- 10 % Diluant d’étalonnage: D5W Température d’étalonnage: 33,3 Celsius Volume nominal + volume résiduel: 96 mL + 1 mL Volume maximal: 130 mL Durée nominale d’administration: 96, 48 et 32 heures
Dispositif de remplissage de seringues
Maintient les tubulures de la pompe lors du remplissage de seringues uniques et de distributeurs de médicaments à administration orale.
Infusor LV 2, 3, 5
Item #: 2C1155KP
Infusor LV 2, 3, 5 Débit nominal: 2, 3, 5 mL/h Précision: +/- 10 % Diluant d’étalonnage: D5W Température d’étalonnage: 33,3 Celsius Volume nominal + volume résiduel: 24 mL + 3 mL Volume maximal: 300 mL Durée nominale d’administration: 120, 80 et 48 heures
Infusor XLV 8
Item #: 2C1168K
Infusor XLV 8 Débit nominal: 8 mL/h Précision: +/- 15 % Diluant d’étalonnage: NS Température d’étalonnage: 31,1 Celsius Volume nominal + volume résiduel: 576 mL + 5 mL Volume maximal: 600 mL Durée nominale d’administration: 3 jours
Intermate SV 100 sans DEPH
Item #: 2C2117K
Intermate SV 100 sans DEPH Débit nominal: 100 mL/h Précision: +/- 15 % Diluant d’étalonnage: NS Température d’étalonnage: 21,1 Celsius Volume nominal + volume résiduel: 100 mL + 1 mL Volume maximal: 105 mL Durée nominale d’administration: 30 minutes
Intermate SV 200 sans DEPH
Item #: 2C2118K
Intermate SV 200 sans DEPH Débit nominal: 200 mL/h Précision: +/- 15 % Diluant d’étalonnage: NS Température d’étalonnage: 21,1 Celsius Volume nominal + volume résiduel: 100 mL + 1 mL Volume maximal: 105 mL Durée nominale d’administration: 30 minutes
Intermate LV 100 sans DEPH
Intermate LV 100 sans DEPH Débit nominal: 100 mL/h Précision: +/- 15 % Diluant d’étalonnage: NS Température d’étalonnage: 21,1 Celsius Volume nominal + volume résiduel: 275 mL + 3 mL Volume maximal: 275 mL Durée nominale d’administration: 2,5 heures
Intermate LV 250 sans DEPH
Intermate LV 250 sans DEPH Débit nominal: 250 mL/h Précision: +/- 15 % Diluant d’étalonnage: NS Température d’étalonnage: 21,1 Celsius Volume nominal + volume résiduel: 250 mL + 3 mL Volume maximal: 275 mL Durée nominale d’administration: 1 heure
Intermate XLV 250 sans DEPH
Intermate XLV 250 sans DEPH Débit nominal: 250 mL/h Précision: +/- 15 % Diluant d’étalonnage: NS Température d’étalonnage: 21,1 Celsius Volume nominal + volume résiduel: 500 mL + 5 mL Volume maximal: 550 mL Durée nominale d’administration: 2 heures
Secondary Medication Set, DUO-VENT, For use with CLEARLINK System. 60 drops/mL. 37" (93 cm). Non-DEHP
CL NON-DEHP SEC MED SET 60DPMLUERLOCK & HANGER NO DISTAL CO
Solution Set, DUO-VENT, 3 CLEARLINK Luer Activated Valves, 119" (3.0 m), Non-DEHP Pump Segment, Polyethylene (PE) Lined Tubing
Solution Set, DUO-VENT Spike with Polyethylene (PE) Lined Tubing and 3 CLEARLINK Luer Activated Valves, Male Luer Lock Adapter with Retractable Collar. Approximately 10 drops/mL. Approximate Length 119" (3.0 m). Non-DEHP Pump Segment. Sterile Fluid Path. Fluid path does not contain DEHP: Outer layer of polyethylene lined tubing contains DEHP.
ADAPTACAP Bottle Adapter, 33 mm Long Neck
ADAPTACAP Bottle Adapter, Threaded, Tethered and Re-closable Cap. Converts a standard prescription bottle into a filling device for use with EXACTAMED Oral Dispensers. Long Syringe Neck, 33 mm (20/Pack 100/Case)
ADAPTACAP Bottle Adapter, 28 mm Long Neck
ADAPTACAP Bottle Adapter, Threaded, Tethered and Re-closable Cap. Converts a standard prescription bottle into a filling device for use with EXACTAMED Oral Dispensers. Long Syringe Neck, 28 mm (20/Pack 100/Case)
ADAPTACAP Bottle Adapter, 24 mm Standard
ADAPTACAP Bottle Adapter, Threaded, Tethered and Re-closable Cap. Converts a standard prescription bottle into a filling device for use with EXACTAMED Oral Dispensers. Standard Syringe Neck, 24 mm (20/Pack 100/Case)
ADAPTACAP Bottle Adapter, Threaded, 24 mm Standard
ADAPTACAP Bottle Adapter, Threaded, Tethered and Re-closable Cap. Converts a standard prescription bottle into a filling device for use with EXACTAMED Oral Dispensers. Standard Syringe Neck, 24 mm (20/Pack 100/Case)
QNRG+ Antibacterial/Antiviral Filter for Canopy and Mask Modes
The single use filter is used when canopy mode or mask mode testing is performed with the QNRG+ Metabolic Monitor. The purpose of the filter is to avoid cross-contamination. Inquiries regarding PVC/DEHP status should be referred to COSMED.
QNRG+ Heat Moisture Exchanger (HME) Antibacterial/ antiviral Filter
The HME Heat Moisture Exchanger with Antibacterial/Antiviral filter, with a luer lock port, is used for Ventilator mode testing with the QNRG+ Metabolic Monitor when the ventilator circuit does not have an active humidifier
Q-NRG+ Cart with Cylinder Holder w/o clamp
The QNRG+ rolling Pole Cart, with Cylinder holder, allows easy transportation of the QNRG+ Metabolic Monitor, as well as its accessories and disposables, to the patient site